CHERYLAS- varicose vein


EVLA treatment
The procedures are generally performed on an ambulatory basis with local anesthetic and typically require no edation. The patients are fully ambulatory following treatment, and the recovery time is short. In this article.

EVLA mechanism of action
The underlying goal for all thermal ablation procedures is to deliver sufficient thermal energy to the wall of an incompetent vein segment to produce irreversible occlusion, fibrosis, and ultimately disappearance of the vein. The mechanism of vein wall injury after EVLA is controversial. It has been postulated to be mediated both by direct effect and indirectly via laser-induced steam generated by the heating of small amounts of blood within the vein. Adequately damaging the vein wall with thermal energy is imperative to obtain effective ablation. Some heating may occur by direct absorption of photon energy (radiation) by the vein wall, as well as by convection from steam bubbles and conduction from heated blood. However, these later mechanisms are unlikely to account for most of the impact on the vein.

Diode lasers advantage
Diode lasers are most commonly used for EVLA. Laser generators exist with multiple different wavelengths, including lower wavelengths that are considered hemoglobin specific and include 810 nm, 940 nm, 980 nm, and 1064 nm. Higher wavelengths are considered water specific and include 1320 nm and 1470 nm. Although it is still not definitively established in the literature, some authors suggest that the higher wavelength lasers produce similar efficacy at lower power settings with less postprocedure symptoms.

Accessory
It can be performed with multiple different laser fiber designs (ie, bare-tip fibers, jacket-tip fibers radial fibers) and diameters available from a variety of vendors. Each of the fiber designs has been demonstrated to be effective in closing the saphenous vein.

Specifications

Laser Name
CHERYLAS
Laser Type
GaAlAs Diode Laser
Wavelength
810nm/ 940nm/ 980nm/ 1470nm
Maximum Power
15W/ 30W/ 60W
Operation Mode
CW, Single Or Repeat Pulse
Pulse Duration
10us- 3s
Repetition Rate
0.2Hz- 50KHz
Pilot Beam
Red Diode Laser Of 650nm, Power<5mW
Control Mode
True Color Touch Screen
Transmission System
Medical Fibers With SMA905 Connector
Dimensions
380(W)*430(L)*220(H) mm
Weight
11Kg

Comments

Popular posts from this blog

Best Diode Laser for Veterinary Laser Surgery

Class IV Lasers in Physical Therapy

Peralas- Affordable 980nm Diode High Intensity Laser Therapy Equipment Back Treatment